Danfoss ContactorDanfoss CI 6 - CI 50 Contactors

CSE's Southampton branch is a Danfoss Low Voltage partner with an extensive range of Danfoss stock.  Ray Hargreaves and the team also have specialist Danfoss knowledge and training to assist our customers with their enquiries. 

The contactor programme CI 6-50 is based on three frame sizes. The smallest frame size consists of CI 6-15 (2.2-7.5 kW), the middle contains the CI 16-30 range (7.5-15 kW) and the largest frame size is represented by the CI 32-50 (15-25 kW). All frame sizes are provided with three NO main contacts. CI 6-15 are available with four NO main contacts.

A long electrical lifetime makes the CI 6-50 contactors suitable for operation of all kinds of electrical loads in modern industry. Combined with a thermal overload relay, the contactor switches and protects induction motors against overload and asymmetric load.

A wide range of clip-on aux. contacts, timers, surge suppressors, mechanical interlock and marking plates makes the CI 6-50 programme very flexible and suitable both for OEMs and panel builders.

  • Compact design in three frame sizes
  • Screw or DIN rail mounting
  • Power range 2.2 to 25 kW
  • For ac coil voltages

Ordering Information

Contactors CI 6-50 for a.c. coil voltage (no built in auxiliary contacts)

Main Circuit Auxiliary Contacts Code no.
1)
Type
AC-3 Load Ith 4)
(AC-1)
Open A
Ithe5)
(AC-1)
Encl. A
Max. Ith 6)
(AC-1)
Open A
Main contacts
(make)
Number
Ue
220-240V
kW
Ue
380-690 V
kW
Ie
A
Add-on options
Number
1.5 2.2 6 20 16 - 3 1-4 037H0015 CI 6  2)
1.5 2.2 6 20 16 - 4 1-4 037H0018 CI 6  2)
2.2 4.0 9 25 16 - 3 1-4 037H0021 CI9
2.2 4.0 9 25 16 - 4 1-4 034H0022 CI 9
3.0 5.5 12 25 20 - 3 1-4 037H0031 CI 12
3.0 5.5 12 25 20 - 4 1-4 037H0032 CI 12
4.0 7.5  3) 16 25 20 30 3 1-4 037H0049 CI 15
4.0 7.5  3) 16 25 20 30 4 1-4 037H0050 CI 15
4.0 7.5 16 40 25 45 3 1-4 037H0041 CI 16
5.5 10.0 20 40 25 45 3 1-4 037H0045 CI 20
5.5 11.0 25 40 25 45 3 1-4 037H0051 CI 25
7.5 15.0 30 40 30 50 3 1-4 037H0055 CI 30
8.5 15.0  3) 32 63 63 - 3 1-4 037H0061 CI 32
10.0 18.5  3) 37 80 63 - 3 1-4 037H0056 CI 37
11.0 22.0  3) 45 80 80 90 3 1-4 037H0071 CI 45
15.0 25.0  3) 52 80 80 90 3 1-4 037H0080 CI 50

1) Coil voltage / frequency or Suffic no (see table below) must be added to the Danfoss code no.
2) AC-15 operation : max. 500 VA/6 A
3)  Ue max. : 500V
4)  The thermal current value Ith gives the maximum load at 40oC, which corresponds to installing the contactor in air (open)
5) The thermal current value Ith gives the maximum load at 60oC, corresponding installing the contactor inside an enclosure
6) Heat -resistant leads (min. 75oC) must be used.

a.c. coil voltages and coils for CI 6-50

Coil Voltage * Suffix No. Coils for CI 6 - 30 Coils for CI 32 - 50
Code No. Code No.
12 V, 50-60 Hz 12 037H6486  1) -
20 V, 50 Hz / 24 V, 60 Hz 14 037H6461 037H6061
24 V, 50-60 Hz 13 037H6484  1) 037H6084  1)
24 V, 50 Hz / 29 V, 60 Hz 16 037H6462 037H6062
42 V, 50 Hz / 50 V, 60 Hz 17 037H6463 037H6063
48 V, 50 Hz / 57 V, 60 Hz 18 037H6464 037H6064
92 V, 50 Hz / 110 V, 60 Hz 21 037H6465 037H6065
110 V, 50 - 60 Hz 23 037H6487  1) 037H6087  1)
115 V, 60 Hz 24 037H6451  2) -
110 V, 50 Hz  / 132 V, 60 Hz 22 037H6466 037H6066
167 V, 50 Hz / 200 V, 60 Hz 91 037H6470 -
208-230 V, 60 Hz 28 037H6450  2) 037H6050  2)
183 V, 50 Hz / 220 V, 60 Hz 29 037H6469 037H6069
200 V, 50 Hz / 240 V, 60 Hz 30 037H6471 037H6071
220-230 V, 50 Hz / 220 V, 60 Hz 32 037H6488  1) 037H6088  1)
220 - 230 V, 50 Hz 31 - 037H6072
220 - 240 V, 50 Hz 31 037H6472 -
240 V, 50 Hz / 288V, 60 Hz 33 - 037H6073
317V, 50 Hz / 380V, 60Hz 92 037H6476 -
380 - 400V, 50 Hz / 440 V, 60 HZ 37 037H6478 0376078
380 V, 50 Hz 96 037H6485  3) -
415 V, 50 Hz / 500 V, 60 Hz 38 037H6479 037H6079
440 V, 50 Hz / 550 V, 60 Hz 93 037H6477 -
500 V, 50 Hz / 600 V, 60 Hz 94 037H6481 037H6081

Danfoss Contactor*) Standard Coil Voltage : -15%, +10%

1) Double frequency coil : voltage range ±10%
Continuous operation : ambient temperature max. 55oC, non-enclosed
Intermittent operation : energised for 30 min / hour : ambient temperature max. 65oC

2) Operating conditions and tolerances as for double frequency coils

3) Undervoltage coil : voltage tolerance -35 to 0%

Contactor Ordering

Example : CI 9 with four main contacts and 24 V, 50 Hz coil voltage:
Select one of the following two forms of ordering:
Danfoss code No. + suffix No. : 037H0022.16
or Danfoss Code No + coil voltage / frequency : 037H0022, 24V V/50 Hz

Auxiliary Contact Blocks CB for CI 6 - 50

Contact Function Load Colour Code  Code No. Type
Ie
(AC-15)
Ith  1)
(AC-1)
Open
Ithe  2)
(AC-1)
Enc.
Ue
A A A V
start 6 10 10 500 green 037H0110 CB-S
start pulse  3) 6 10 10 500 green 037H0117 CB-I
make 6 10 10 500 green 037H0111 CB-NO
break 6 10 10 500 red 037H0112 CB-NC
early make 6 10 10 500 white 037H0113 CB-EM
late break 6 10 10 500 blue 037H0114 CB-LB

1) The thermal current value Ith gives the maximum load at 40o, which corresponds to installing the contactor in air (open)
2) The thermal current value  Ithe gives the maximum load at 60o, corresponding installing the contactor inside an enclosure.
3) Without self-holding function