FC202 Danfoss Aqua Drive

AquaDrive-2

Danfoss VLT® AQUA Drive is dedicated to water and wastewater applications. With a wide range of powerful standard and optional features, the AQUA Drive provides the lowest overall cost of ownership as a result of energy savings and easy maintenance.

Power and voltage range
200-240 V ….. 0.25 kW – 45 kW
380-480 V ….. 0.37 kW – 1000kW
525-600 V ….. 0.75 kW – 90 kW
525-690 V ….. 11 kW – 1.4 MW

Three phase
3*200-240V… 0,25-45kW
3*380-480V… 0,37-1000kW
3*525-600V… 0,75-90kW
3*525-690V… 11-1.4 MW

Single phase
1*200-240V 1.1-22kW
1*380-480V 7.5-37kW

Enclosures – IP20/chassis, IP21/NEMA 1, IP55/NEMA 12 and IP66/NEMA 4X
Dedicated water features Auto tuning of the PI controllers – With auto tuning of the PI controllers, the drive monitors how the system reacts on corrections made by the drive – and learns from it, so that precise and stable operation is achieved quickly.
Automatic Energy Optimization – The standard feature AEO provides optimized motor magnetization at all speeds and loads. This increases energy efficiency by 5-15% for partial loads.
Energy monitoring – The VLT AQUA Drive provides a complete range of energy consumption information, which helps identify low-efficiency components in the system.
PM motor support – Support for any non salient permanent magnet motor up to 22 kW for better system efficiency.
Pipe Fill Mode – Enables controlled (closed loop) filling of pipes. Prevents water hammering, bursting water pipes or blowing off sprinkler heads.
End of Pump Curve detects breaks and leakage – The feature detects breaks and leakage. End of curve triggers an alarm, shuts off the pump or performs another userdefined action.
Dry Pump Protection lowers maintenance costs – The VLT® AQUA Drive constantly evaluates the condition of the pump, based on internal frequency/power measurements.
Deragging – Can be used as a proactive or reactive feature of the AQUA Drive for wastewater applications to prevent clogging of pumps. Deragging helps to avoid downtime and reduces maintenance cost.
Cascade controller solutions – The built-in standard cascade controller controls up to three pumps with a fixed lead pump. The optional Extended and Advanced Cascade Controller makes it possible to extend the number of pumps and ensure smooth staging/de-staging, also in mixed pump and variable speed pump applications.
Motor Alternation – This built-in logic controls alternation between two pumps in duty/stand-by applications. Motion of the stand-by pump prevents the pump from sticking. An internal timer assures equal usage of the pumps.
Flow compensation – The flow compensation feature reduces the pressure set point according to the flow, which saves energy.
Initial/Final Ramp – The initial ramp provides fast acceleration of pumps to minimum speed, from where the normal ramp takes over. This prevents damage on thrust and bearings.
Check Valve Ramp – The Check Valve Ramp of the VLT AQUA Drive prevents water hammering as check valves close smoothly when the pump stops.
Quick Menu – The user-friendly Quick Menu and its submenus of the VLT AQUA Drive, saves time during drive configuration. The submenu “Water and Pumps” provides direct access to application specific features.
Safety – The VLT® AQUA Drive can optionally be delivered with the safe torque off (safe stop) functionality suitable for category 3, performance level d according to EN 13849-1 and SIL 2 according to IEC 62061/IEC 61508. This feature prevents the drive from starting unintended.

Accessories – A wide selection of accessories is available for the VLT® AQUA Drive to suit your needs. For further details see the Operation Instructions.

Options – Options for bus communication, user programs, etc., are delivered ready for plug and play.
Display options – Local Control Panel LCP (graphical and numerical), Cable for LCP, 3 m [9,8 ft.], Remote-mounting kit for Local Control Panel (LCP), Blind cover

Fieldbus options – VLT PROFIBUS DP/V1 MCA 101, VLT DeviceNet MCA 104, VLT PROFINET MCA 120, VLT EtherNet IP MCA 121, VLT Modbus TCP MCA 122
I/O options – VLT Extended I/O MCB 101, VLT Relay Card MCB 105), VLT Extended Cascade Controller MCO 101, VLT Advanced Cascade Controller MCO 102, VLT Analog I/O MCB 109, VLT PTC Thermistor Card MCB 112, VLT Sensor Input MCB 114
Filters – VLT Advanced Harmonic Filter AHF 005/010, VLT Sine-wave Filter MCC 101, VLT dU/dt Filter MCC 102, VLT Common Mode Filter MCC 105

PC software tools – VLT Motion Control Tool MCT 10 for commissioning and servicing, VLT Motion Control Tool MCT 31 for calculating harmonic distortion

Other accessories – VLT 24V external supply MCB 107, IP21/NEMA1 Kit, Kit for panel through mount, USB connection cable to PC

Dimenions
Dimensions – See pdf
Drive Options
For further options see pdf (includes descriptive codes)
Order Codes – For basic Drives 380-480 VAC

If add ons such as brake, profibus, backnet, fuse or a 24V Back up is required please contact us for a taylor made quote email – southampton@cseuk.com or telephone – 02380 255757. For further options see pdf link above.

Order Code (IP20) Order Code (IP55) KW Amps Filter
131B8872 131B8875 0.37 1.3 H1
131B8880 131B8883 0.55 1.8 H1
131B8888 131B8891 0.75 2.4 H1
131B8896 131B8900 1.1 3 H1
131B8290 131F0652 1.5 4.1 H1
131B8906 131B8909 2.2 5.6 H1
131B8914 131B8917 3.0 7.2 H1
131B8932 131B9332 4.0 10 H1
131B8942 131B8947 5.5 13 H1
131B8289 131B8972 7.5 16 H1
131F6639 131B9001 11 24 H1
131F6644 131B9008 15 32 H1
131F6648 131B9016 18.5 37.5 H1
131F6768 131B9025 22 44 H1
131F6773 131B9038 30 61 H1
131F6778 131B9046 37 73 H1
131F6653 131B9053 45 90 H1
131F6657 131B9064 55 106 H1
131F6661 131B9071 75 147 H1
131F6666 131B9078 90 177 H1
** Drives available up to 900KW Please contact for more details.
Data sheet
For more information or price enquiries please contact southampton@cseuk.com or telephone – 02380 255757

Want Monthly Offers, Promotions & News?

Sign up now to be the first to know about special offers, product news and industry information.

Thank you for signing up to the newsletter