Danfoss VLT® AQUA Drive is dedicated to water and wastewater applications. With a wide range of powerful standard and optional features, the AQUA Drive provides the lowest overall cost of ownership as a result of energy savings and easy maintenance.
Power and
voltage range
200-240 V ….. 0.25 kW – 45 kW
380-480 V ….. 0.37 kW – 1000kW
525-600 V ….. 0.75 kW – 90 kW
525-690 V ….. 11 kW – 1.4 MW
Three phase
3*200-240V… 0,25-45kW
3*380-480V… 0,37-1000kW
3*525-600V… 0,75-90kW
3*525-690V… 11-1.4 MW
Single phase
1*200-240V 1.1-22kW
1*380-480V 7.5-37kW
Enclosures
–
IP20/chassis, IP21/NEMA 1, IP55/NEMA 12 and IP66/NEMA 4X
Dedicated
water features Auto tuning of the PI controllers
– With
auto tuning of the PI controllers, the drive
monitors how the system reacts on
corrections made by the drive
– and learns from it, so that
precise and stable operation is achieved quickly.
Automatic
Energy Optimization
– The standard feature AEO provides
optimized motor magnetization at all speeds and loads. This increases energy
efficiency by 5-15% for partial loads.
Energy
monitoring
– The VLT AQUA Drive provides a complete range of energy
consumption information, which helps identify low-efficiency components in the
system.
PM
motor support
– Support for any non salient permanent magnet motor up to 22
kW for better system efficiency.
Pipe
Fill Mode
– Enables controlled (closed loop) filling of pipes. Prevents water
hammering, bursting water pipes or blowing off sprinkler heads.
End
of Pump Curve detects breaks and leakage
– The feature detects
breaks and leakage. End of curve triggers an alarm, shuts off the pump or
performs another userdefined action.
Dry
Pump Protection lowers maintenance costs
– The VLT® AQUA Drive
constantly evaluates the condition of the pump, based on internal
frequency/power measurements.
Deragging
– Can be
used as a proactive or reactive feature of the AQUA Drive for wastewater applications
to prevent clogging of pumps. Deragging helps to avoid downtime and reduces
maintenance cost.
Cascade
controller solutions
– The built-in standard cascade controller
controls up to three pumps with a fixed lead pump. The optional Extended and Advanced
Cascade Controller makes it possible to extend the number of pumps and ensure
smooth staging/de-staging, also in mixed pump and variable speed pump
applications.
Motor
Alternation
– This built-in logic controls alternation between two pumps in
duty/stand-by applications. Motion of the stand-by pump prevents the pump from
sticking. An internal timer assures equal usage of the pumps.
Flow
compensation
– The flow compensation feature reduces the pressure set point
according to the flow, which saves energy.
Initial/Final
Ramp
– The initial ramp provides fast acceleration of pumps to
minimum speed, from where the normal ramp takes over. This prevents damage on
thrust and bearings.
Check
Valve Ramp
– The Check Valve Ramp of the VLT AQUA Drive prevents water
hammering as check valves close smoothly when the pump stops.
Quick
Menu
– The user-friendly Quick Menu and its submenus of the VLT AQUA
Drive, saves time during drive configuration. The submenu “Water and
Pumps” provides direct access to application specific features.
Safety
– The
VLT® AQUA Drive can optionally be delivered with the safe torque off (safe
stop) functionality suitable for category 3, performance level d according to
EN 13849-1 and SIL 2 according to IEC 62061/IEC 61508. This feature prevents
the drive from starting unintended.
Accessories – A wide selection of accessories is available for the VLT® AQUA Drive to suit your needs. For further details see the Operation Instructions.
Options – Options for bus communication, user programs, etc.,
are delivered ready for plug and play.
Display options – Local Control Panel LCP
(graphical and numerical), Cable for LCP, 3 m [9,8 ft.], Remote-mounting kit
for Local Control Panel (LCP), Blind cover
Fieldbus
options
– VLT PROFIBUS DP/V1 MCA 101, VLT DeviceNet MCA 104, VLT
PROFINET MCA 120, VLT EtherNet IP MCA 121, VLT Modbus TCP MCA 122
I/O
options
– VLT Extended I/O MCB 101, VLT Relay Card MCB 105), VLT
Extended Cascade Controller MCO 101, VLT Advanced Cascade Controller MCO 102,
VLT Analog I/O MCB 109, VLT PTC Thermistor Card MCB 112, VLT Sensor Input MCB
114
Filters
– VLT
Advanced Harmonic Filter AHF 005/010, VLT Sine-wave Filter MCC 101, VLT dU/dt
Filter MCC 102, VLT Common Mode Filter MCC 105
PC software tools – VLT Motion Control Tool MCT 10 for commissioning and servicing, VLT Motion Control Tool MCT 31 for calculating harmonic distortion
Other accessories – VLT 24V external supply MCB 107, IP21/NEMA1 Kit, Kit for panel through mount, USB connection cable to PC
Dimensions – See pdf |
For further options see pdf (includes descriptive codes) |
Order Codes – For basic Drives 380-480 VAC |
If add ons such as brake, profibus, backnet, fuse or a 24V Back up is required please contact us for a taylor made quote email – southampton@cseuk.com or telephone – 02380 255757. For further options see pdf link above. |
Order Code (IP20) | Order Code (IP55) | KW | Amps | Filter |
131B8872 | 131B8875 | 0.37 | 1.3 | H1 |
131B8880 | 131B8883 | 0.55 | 1.8 | H1 |
131B8888 | 131B8891 | 0.75 | 2.4 | H1 |
131B8896 | 131B8900 | 1.1 | 3 | H1 |
131B8290 | 131F0652 | 1.5 | 4.1 | H1 |
131B8906 | 131B8909 | 2.2 | 5.6 | H1 |
131B8914 | 131B8917 | 3.0 | 7.2 | H1 |
131B8932 | 131B9332 | 4.0 | 10 | H1 |
131B8942 | 131B8947 | 5.5 | 13 | H1 |
131B8289 | 131B8972 | 7.5 | 16 | H1 |
131F6639 | 131B9001 | 11 | 24 | H1 |
131F6644 | 131B9008 | 15 | 32 | H1 |
131F6648 | 131B9016 | 18.5 | 37.5 | H1 |
131F6768 | 131B9025 | 22 | 44 | H1 |
131F6773 | 131B9038 | 30 | 61 | H1 |
131F6778 | 131B9046 | 37 | 73 | H1 |
131F6653 | 131B9053 | 45 | 90 | H1 |
131F6657 | 131B9064 | 55 | 106 | H1 |
131F6661 | 131B9071 | 75 | 147 | H1 |
131F6666 | 131B9078 | 90 | 177 | H1 |
** Drives available up to 900KW Please contact for more details. |
For more information or price enquiries please contact southampton@cseuk.com or telephone – 02380 255757 |