Cable Application
Can be used in dry, damps and wet rooms. Due to the screening of single cores of bundles this cable is suitable for EMC-critical use.
- Temperature range flexible: – 5° C to + 70° C
- Temperature range static: – 40° C to + 70° C
Voltage : Working voltage: 250/500 V; test voltage: 1200 V
Cable Construction
- fine bare copper conductors
- strand structure according to VDE 0295, class 5
- PVC insulation
- Core marking:
- up to 5 cores colour coded in accordance to VDE 0293
- 7 cores and over black with printed consecutive number coding
- earth conductor green l yellow
- cores twisted in bunches and screened
- PVC outer sheath, black
- suitable in low temperatures
- bending radius: 10 x Ø
Cores | Cross Section mm2 | Outer Diameter mm | Copper Weight kg / 100m | Weight kg / 100m | ||
4 cores individually screened | ||||||
14 | x | 3 x 1.00 | 100 x 10.3 | 55.1 | 151 | |
Screened by bunches | ||||||
5 | x | 0.5 | 21 x 3.4 | 6.14 | 9.2 | |
5 | x | 4 x 0.5 | 37.4 x 7.2 | 16 | 28 | |
8 | x | 7 x 0.5 | 63.8 x 11.1 | 48 | 65 | |
4 | x | 4 x 1.00 | 33.5 x 11 | 31 | 35 | |
6 | x | 2.5 | 37.4 x 7.2 | 24 | 32 | |
5 | 4 x 0.50 | 35.5 x 9.2 | 16 | 51.4 | ||
7 | x | 4 x 0.50 | 50 x 10.3 | 22.2 | 74.5 | |
14 | x | 4 x 0.50 | 100 x 10.3 | 44.4 | 149 | |
7 | x | 3 x 1.00 | 50 x 10.3 | 27.5 | 75.5 | |
7 | x | 3 x 1.00 | 50 x 10.3 | 21.2 | 72 | |
Screened by bunches, cold resistant and waterproof | ||||||
4 | x | 1.5 | OB | 18.8 x 7 | 9.1 | 21 |
8 | x | 1.5 | JZ | 35.5 x 5.8 | 19 | 40 |
8 | x | 1.5 | OZ | 35.5 x 5.8 | 19 | 40 |
12 | x | 1.5 | OZ | 50 x 6 | 33 | 61 |
4 | x | 2.5 | JB | 21 x 6.9 | 16.8 | 27 |
4 | x | 4 | JB | 24.4 x 7.6 | 20.8 | 40 |
4 | x | 6 | JB | 29.4 x 9.1 | 32.5 | 52 |
4 | x | 10 | JB | 35.8 x 10.5 | 51.8 | 84 |