Reeling Flat Cables with/without Integrated Optical Fibers 3.6/6 (7.2) kV 6/10 (12) kV 8.7/15 (18) kV
Applications
Flexible flat reeling cable for data transmission and for energy supply. Especially for high and extreme mechanical stress used in Ship to Shore Cranes (STS), Rail Mounted Gantry Cranes (RMG) and other heavy mobile equipment.
Design
1. Conductor : Flexible, plain copper, “FSC” better than IEC 60228 class 5
2. Insulation : Inner semi-conductive layer New special insulation compound “RHEYCLEAN” based on EPDM, better than DIN VDE 207 part 20.
Outer semi-conductive layer, “RHEYSTRIP”, easy strip design
3. Protective earth conductor Individually concentric mixed braid of tinned copper wires and high-tech polyamid yarn
4. Optical Fibre : Fibre diameter 9/125 μm; 50/125 μm; 62.5/125 μm
5. Outer sheath : Special rubber compound; Colour: red
Marking
RHEYFIRM(RS)-FLAT (N)TSFLCGCWOEUS
Number of cores – cross-section Voltage – NEXANS – year
Core Identification
Parallel arranged
Standards
In line with
DIN VDE 0250 part 813
DIN VDE 0295
DIN VDE 0298
DIN VDE 0472
pr EN 50363
Mechanical properties
Tensile stress of the conductor | 20 N/mm2 |
Bending radii | according to DIN VDE 298, |
Tests | Bending test |
Reeling speed | on request |
Chemical properties
Oil resistant.
For indoor and outdoor applications. Moisture, UV and ozone resistance.
Flame-retardant according to IEC 60 332 part 1.
Electrical, Optical and Thermal properties
Nominal voltage | Uo/U | 3.6/6 kV to 8.7/15 kV |
Maximum operation voltage in AC systems | Um | 1.2 x U |
Maximum operation voltage in DC systems | Vm | 1.8 x U |
Test voltage (according to DIN VDE 0250 part 813) | 11 kV to 24 kV in AC | |
27.5 kV to 60 kV in DC | ||
Current rating (A) | according to DIN VDE 0298 part 4, | |
see electrical characteristics page 3.2 B | ||
Max. temperature at the conductor: | ||
– in service | + 90 °C | |
– under short-circuit conditions | + 250 °C | |
Max. surface temperature: | ||
– fixed installation | – 50 °C up to + 80 °C | |
– mobile operation | – 35 °C up to + 80 °C |
Number of cores and nominal cross-section |
Outer dimensions | Weight approx. |
Tensile strength |
|
(mm2) | Min. (mm) | Max. (mm) | (kg/km) | (N) |
3.6/6 kV | ||||
4 x 35 | 24 x 77 | 25 x 79 | 3,600 | 2,800 |
3 x 35/35 + OFE | 24 x 77 | 25 x 79 | 3,600 | 2,100 |
4 x 50 | 26 x 83 | 27 x 85 | 4,400 | 4,000 |
3 x 50/50 + OFE | 26 x 83 | 27 x 85 | 4,400 | 3,000 |
6/10 kV | ||||
4 x 35 | 26 x 78 | 27 x 80 | 3,900 | 2,800 |
3 x 35/35 + OFE | 26 x 78 | 27 x 80 | 3,900 | 2,100 |
8.7/15 kV | ||||
4 x 35 | 27 x 79 | 28 x 81 | 4,200 | 2,800 |
3 x 35/35 + OFE | 27 x 79 | 28 x 81 | 4,200 | 2,100 |
Options
- Voltage level 0.6/1 (1.2) kV on request
- Other sheath qualities and colours
- Including signal cores, telecommunication cores
- Pre-assembled with sealing ends upon request